Skip to main content
SLU publication database (SLUpub)
Review article - Peer-reviewed, 2023

Maternal and newborn plasma oxytocin levels in response to maternal synthetic oxytocin administration during labour, birth and postpartum - a systematic review with implications for the function of the oxytocinergic system

Buckley, Sarah; Uvnas-Moberg, Kerstin; Pajalic, Zada; Luegmair, Karolina; Ekstrom-Bergstrom, Anette; Dencker, Anna; Massarotti, Claudia; Kotlowska, Alicja; Callaway, Leonie; Morano, Sandra; Olza, Ibone; Magistretti, Claudia Meier

Abstract

BackgroundThe reproductive hormone oxytocin facilitates labour, birth and postpartum adaptations for women and newborns. Synthetic oxytocin is commonly given to induce or augment labour and to decrease postpartum bleeding.AimTo systematically review studies measuring plasma oxytocin levels in women and newborns following maternal administration of synthetic oxytocin during labour, birth and/or postpartum and to consider possible impacts on endogenous oxytocin and related systems.MethodsSystematic searches of PubMed, CINAHL, PsycInfo and Scopus databases followed PRISMA guidelines, including all peer-reviewed studies in languages understood by the authors. Thirty-five publications met inclusion criteria, including 1373 women and 148 newborns. Studies varied substantially in design and methodology, so classical meta-analysis was not possible. Therefore, results were categorized, analysed and summarised in text and tables.ResultsInfusions of synthetic oxytocin increased maternal plasma oxytocin levels dose-dependently; doubling the infusion rate approximately doubled oxytocin levels. Infusions below 10 milliunits per minute (mU/min) did not raise maternal oxytocin above the range observed in physiological labour. At high intrapartum infusion rates (up to 32 mU/min) maternal plasma oxytocin reached 2-3 times physiological levels.Postpartum synthetic oxytocin regimens used comparatively higher doses with shorter duration compared to labour, giving greater but transient maternal oxytocin elevations. Total postpartum dose was comparable to total intrapartum dose following vaginal birth, but post-caesarean dosages were higher.Newborn oxytocin levels were higher in the umbilical artery vs. umbilical vein, and both were higher than maternal plasma levels, implying substantial fetal oxytocin production in labour. Newborn oxytocin levels were not further elevated following maternal intrapartum synthetic oxytocin, suggesting that synthetic oxytocin at clinical doses does not cross from mother to fetus.ConclusionsSynthetic oxytocin infusion during labour increased maternal plasma oxytocin levels 2-3-fold at the highest doses and was not associated with neonatal plasma oxytocin elevations. Therefore, direct effects from synthetic oxytocin transfer to maternal brain or fetus are unlikely. However, infusions of synthetic oxytocin in labour change uterine contraction patterns. This may influence uterine blood flow and maternal autonomic nervous system activity, potentially harming the fetus and increasing maternal pain and stress.

Keywords

Oxytocin; Maternal oxytocin; Newborn oxytocin; Synthetic oxytocin; Pitocin; Syntocinon; Postpartum oxytocin; Induction of labour; Augmentation of labour

Published in

BMC Pregnancy and Childbirth
2023, Volume: 23, number: 1, article number: 137
Publisher: BMC

    Associated SLU-program

    SLUsystematic

    UKÄ Subject classification

    Obstetrics, Gynecology and Reproductive Medicine

    Publication identifier

    DOI: https://doi.org/10.1186/s12884-022-05221-w

    Permanent link to this page (URI)

    https://res.slu.se/id/publ/121815